Stencil Cleaner: 5 Rules for Under Stencil Wipe

A stencil cleaner does two jobs at once. It removes the solder paste residue that builds on the underside of the foil, and it clears the paste left inside the apertures so that the next print starts from a known state. Both jobs happen inside the printer, in a cycle that lasts a few seconds, and both are easy to get wrong.

The settings that control it are the cleaning solvent, the wipe paper, the wipe frequency and the vacuum or dry pass that follows. Get them right and the under stencil wipe runs for a whole shift without attention. Get them wrong and the stencil is either smeared with paste or scrubbed until the coating and the foil are damaged.

Stencil cleaner and wipe paper on a solder paste printer

What the Under Stencil Wipe Has to Remove

Every print leaves a thin film of paste on the underside of the stencil, around the apertures and across the area that the squeegee travelled. Left in place, that film transfers to the next board as a smear, and a smear across a fine pitch footprint is a bridge waiting to happen. The wipe removes it before the next print begins.

The second target is the paste inside the aperture itself. Paste that has partly dried does not release cleanly, and it leaves a residue ring that reduces the volume of the next deposit. The wipe is the only routine that touches the inside of the aperture, which is why its frequency matters more than its duration.

Solvent, Water and Hybrid Cleaning

The cleaning solvent has to dissolve the paste chemistry in use. A no clean paste and a water soluble paste respond to different solvents, and a solvent chosen for one will smear the other. Where the line runs both, the stencil should be cleaned with the chemistry that matches the paste currently loaded rather than with whatever is in the reservoir.

Drying speed matters for the same reason. A solvent that evaporates slowly leaves liquid in the apertures, which dilutes the next deposit and changes its rheology. A solvent that flashes off too fast can leave a dried residue that is harder to remove than the paste it replaced, so the working window should be taken from the supplier data rather than from habit.

Wipe Paper and Roller Settings

Wipe paper is a consumable with a specification. It has to absorb solvent evenly, release it at a controlled rate and not shed lint, because a fibre left on the stencil becomes a print defect. Paper that is too dry scrubs the stencil without cleaning it, and paper that is too wet floods the apertures.

The roller tension and the paper speed determine how the paper meets the stencil. Too much tension drags the paper across the surface and wears both the paper and the foil, while too little leaves the paper riding over the apertures without contact. Both settings should be recorded with the recipe so that a change can be returned to a known good state.

Wipe Frequency and Aperture Size

Frequency is the setting most often set by habit and least often justified. The right value depends on the paste, the aperture size, the panel and the environment. A fine pitch panel needs a wipe every few prints, while a coarse board with large apertures can run much longer between cycles.

Wiping too often is not free. Each cycle removes some paste from inside the apertures and replaces it with solvent, and a stencil wiped every print can suffer from deposits that are consistently short. Where the frequency is being changed, the printed volume should be measured on both sides of the change, and the paste volume record is the evidence that the new setting is better.

Vacuum Assist and Dry Passes

Vacuum assist pulls the loosened paste and the solvent vapour away from the stencil instead of letting them settle back into the apertures. It also removes most of the paper dust, which is why a printer with vacuum assist usually produces fewer random print defects than one without. The vacuum path has to be maintained, since a blocked filter turns the feature into decoration.

The dry pass that follows the wet wipe removes residual solvent before the next print. Skipping it saves a second per panel and leaves liquid in the apertures. Where the cycle time is tight, the better answer is a faster drying solvent or a lower solvent dose rather than the removal of the dry pass.

Cleaner Compatibility With the Stencil Coating

A coated stencil is more sensitive to cleaning than a bare foil. Aggressive solvent, high pressure and abrasive paper all shorten the life of the film, and once the coating is worn away the operator keeps expecting performance that is no longer there. The cleaning routine should be chosen for the coating as well as for the paste.

Where a coating is used, the supplier should be asked which chemistries are compatible, and the answer should be written into the printer recipe rather than left to the operator. The failure mode is slow, which is what makes it dangerous. The nanocoating behaviour under different cleaning routines is worth measuring before a new cleaner is introduced.

Cleaning the Stencil at End of Shift

End of shift cleaning is a different operation from the in-line wipe. It removes the paste from the apertures, the frame and the tensioning mesh, and it ends with a full dry before the stencil is stored. Storing a wet stencil promotes corrosion at the mesh and leaves a residue that will contaminate the next build.

The stencil should be stored flat and separated from other foils, because contact between two stencils produces scratches that begin the wear pattern. Where a stencil is kept on a rack, the rack should hold it by the frame rather than by the foil, and the storage condition should be part of the stencil’s record.

Disposal, Fume and Operator Safety

Cleaning solvent waste is chemical waste, and it should be collected and disposed of as such rather than poured into general waste. The volume of waste is set by the solvent dose and the wipe frequency, so a printer that is consuming paper and solvent faster than expected is usually also producing more waste than the process needs.

Fumes from the wipe are released inside the printer enclosure, and most machines extract them. Where the extraction is weak, the vapour reaches the operator, and the solvent should be chosen with the exposure limit in mind. The material data sheet should be available at the machine, not only in an office file.

Records and Consumable Control

The cleaning consumables should be controlled like any other material. Paper and solvent should be recorded by lot, the dose and frequency should be part of the printer recipe, and the wipe unit should be maintained on a schedule. A printer whose cleaning record is missing cannot be compared with itself from one week to the next.

The record also allows a cleaning related defect to be recognised. A rise in bridging, a fall in deposit volume or the appearance of paper fibres on the panel are all traceable to the wipe when the settings and the consumables are logged. The stencil tension should be checked at the same intervals, because a foil that has lost tension behaves differently under the wipe as well as under the squeegee.

Under stencil wipe removing solder paste residue from a stencil

FAQ

Should the under stencil wipe run on every print? Only for the most demanding fine pitch work. Frequent wiping keeps the stencil clean but also removes paste from inside the apertures and replaces it with solvent, which reduces the deposit volume on the following print. Most processes settle on a frequency between every print and every tenth panel, based on measured volume.

Can water replace solvent in the wipe? Water works for water soluble paste chemistry and for some cleaners designed to work with water, and it avoids the solvent exposure that operators dislike. It does not dissolve no clean paste effectively, and it dries slowly, so the change should be qualified on the actual paste rather than assumed.

Why does the stencil smell of solvent after the wipe? Solvent vapour collects inside the printer and is normally extracted. A persistent smell suggests the extraction is weak, the solvent dose is too high or the dry pass is not running. All three should be checked, because the same conditions that expose the operator also leave liquid in the apertures.

Leave A Comment